Hantek 1008C Automotive Oscilloscope USB 8 Channels PC Based Storage Digital Multimeter Osciloscopio Logic Analyzer Diagnostic-tool
Features:
- Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;
- 8 channels oscilloscope for vehicle testing;
- Auto Ignition Probe;
- 2.4MSa/s real time sampling rate, 12bit vertical resolution;
- spectrum analysis function;
- 10mV/div to 5V/div input sensitivity;
- DAQ card function;
- 8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.
Specifications:
(1) Vehicle Testing
(1) Vehicle Testing
- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition
- Ignition: primary and secondary
- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
- Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
- Performer: Petrol/Diesel
- Starter and charging circuits
(2) Oscilloscope
- 8 channels oscilloscope, 2.4MSa/s real time sampling rate
- 12 bits vertical resolution, spectrum analysis function
(3) Programmable Generator
- 8 channels programmable generator
- Can analog signals of crankshaft, camshaft etc.
(4) Others
- USB 2.0 interface plug and play, and no need extra power supply;
- More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10
Model | Hantek1008C | |
Oscilloscope Mode | ||
Vertical | Analog Channel | 8 |
Input Impedance | Resistance: 1MΩ | |
Input Sensitivity | 10mV/div to 5V/div | |
| Input Coupling | DC |
Resolution | 12 bits | |
Horizontal | Memory Depth | 4K |
Max. Input | 400V (DC+AC Peak) | |
Real-Time Sampling Rate | 2.4MSa/s | |
Time Base Range | 1ns/div to 20000s/div(1-2-5 sequences) | |
Time Base Precision | ±50ppm | |
Trigger | Source | CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8 |
Mode | Edge | |
X-Y Mode | X-Axis Input | CH1 |
Y-Axis Input | CH2 | |
Cursors and Measurement | Voltage Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot |
Time Measurement | Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle | |
Cursors Measurement | Horizontal ,Vertical, Track, Auto Measure Modes | |
Waveform Signal Process | | +,- , x,÷, FFT, Invert |
Voltage Range | | 10mV to 5V/div @ x 1 probe |
100mV to 50V/div @ x 10 probe | ||
10V to 5000V/div @ x 1000 probe | ||
100V to 50000V/div @ x 10000 probe | ||
200mV to 100V/div @ 20:1 | ||
Current Range | | 100mA to 50.0A/div @ CC65(20A) |
1000mA to 500.0A/div @ CC65(65A) | ||
1A to 100.0A/div @ CC650(60A) | ||
10A to 1000.0A/div @ CC650(650A) | ||
1A to 200.0A/div @CC1100(100A) | ||
10A to 2000.0A/div @CC1100(1100A) | ||
Cursor | | Time/frequency difference, voltage difference |
FFT | | Rectangular, Hanning, Hamming, Blackman Window |
Math | | Addition, subtraction, multiplication, division |
Programmable Generator | ||
Channel | | 8 |
Output Level | | LVTTL |
Frequency Range | | 0-250kHz |
Interface | | USB 2.0 |
Power | | No need extra power supply |
Measurement | Size | 185 x 150 x 27 (mm) |
Weight | 0.35KG |
Packing List:
- 1 x 1008C DAQ oscilloscope
- 8 x Crocodile probes/cabl
- 1 x USB Cable
- 1 x CD (driver etc.)
- 1 x Bag
-
Function SelectionThere are three functions of vehicle diagnosis, oscilloscope and signal generator, including 78 types of vehicle diagnosis function.One Button ScreenshotSave the current waveform and generate pictures. Storage location is optional and easy to find.
Reference WaveformOver 80 types of standard reference waveform inside and can be callout or close with one button. It is convenient to be compared.
Measurement Method20 types of automatic measurement method which can be callout or close with one button. It is convenient and visual to read out the result.PrintThe result can be printed with one button and generate diagnosis report which is easy to be saved and recorded.
REF Comparison WaveformThe user can save the waveform as REF format and callout it again when you need to compare the two waveforms catched in different time.
Data StorageThe diagnosis result can be saved as the format of txt, csv, rfc, xls, doc, jpg and etc. It is convenient to be checked and compared later.
8CH Vehicle Diagnosis8CH signal can be measured simultaneously. The measurement voltage of each channel can be adjusted independently. You can choose to open or close each channel.
Waveform RecordSupport to record and replay the waveform. The waveform can be save into the computer hard disk and easy to read. There is no limit to the record time which can long-time measure and record the waveform for troubleshooting.
Multilanguage SupportSupport the display surface in Chinese, English, German language, and it can be switched freely.Cursor MeasurementSupport 4 types of cursor measurement mode -cross,track, horizontal, and vertical.It's easy to read out the time and voltage of irregular signal.
Color and LightnessThe background color is optional as user's preference. And the lightness of waveform and gridding is settable.
USB CommunicationUSB2.0 power supply + communication interface, plug and play, and support hot plugging.
Signal GeneratorSignal generator function, can simulate crankshaft and camshaft signal.
Previous: PCF79XX Carkey Unlocker support Android and IOS Unlock PCF79Xx Car Keys
Next: wiScan T6 PROS Auto DoIP J2534 Diagnostic Programming Tool
Recommend Items
- US$15.99
- US$15.99
- US$189.00
- US$19.90
- US$95.00
- US$369.00
- US$679.00
- US$69.00
- US$480.00
- US$190.00
- US$190.00
- US$16.90
Special Items
- US$298.00
- US$19.90
- US$19.90
- US$29.00
- US$54.90
- US$69.00
- US$190.00
- US$44.90
- US$149.00
- US$79.90
- US$6.90
- US$227.00